Citation
Syed Mohammad Ahsan Shah and Arshad Adam Salema and Nik Suhaimi Mat Hassan and Yosri Mohd Siran and Syahril Anuar Md Rejab (2023) Integrated microwave-steam sterilisation of loose oil palm fruits: enhanced heating uniformity, crude palm oil quality and energy savings. Journal of Oil Palm Research (Malaysia), 35 (3). pp. 456-466. ISSN 2811-4701
Abstract
Loose oil palm fruits are often left uncollected in large quantities while harvesting fresh fruit bunches, which incurs considerable losses in crude palm oil yield. Although the free fatty acid content in loose fruits is undesirably high, microwave sterilisation is known to reduce it significantly. The present study enhanced microwave sterilisation using a new integrated microwave-steam method in which steam exiting the fruits during vaporisation is entrapped and used to complement the heat treatment process. The effect of this new method on the heating uniformity, drying rate, oil extraction rate, crude palm oil quality and energy consumption/cost was investigated. Results showed that up to 25.7% and 13.6% reduction in temperature non-uniformity and energy consumption/cost was achieved with MW-steam heating. Moreover, sterilisation duration was reduced by up to 11.6%. The stacked arrangement of fruits improved microwave absorption efficiency, reducing temperature non-uniformity by up to 45.0% and energy consumption by up to 19.2%. MW-steam sterilisation achieved up to a 10.5% increase in oil extraction rate. Crude palm oil with excellent hydrolytic and oxidative stability was acquired, thus, boosting oil value that can facilitate post-processing in palm oil mills.
Download File
Full text available from:
Official URL: http://jopr.mpob.gov.my/wp-content/uploads/2022/09...
|
Abstract
Loose oil palm fruits are often left uncollected in large quantities while harvesting fresh fruit bunches, which incurs considerable losses in crude palm oil yield. Although the free fatty acid content in loose fruits is undesirably high, microwave sterilisation is known to reduce it significantly. The present study enhanced microwave sterilisation using a new integrated microwave-steam method in which steam exiting the fruits during vaporisation is entrapped and used to complement the heat treatment process. The effect of this new method on the heating uniformity, drying rate, oil extraction rate, crude palm oil quality and energy consumption/cost was investigated. Results showed that up to 25.7% and 13.6% reduction in temperature non-uniformity and energy consumption/cost was achieved with MW-steam heating. Moreover, sterilisation duration was reduced by up to 11.6%. The stacked arrangement of fruits improved microwave absorption efficiency, reducing temperature non-uniformity by up to 45.0% and energy consumption by up to 19.2%. MW-steam sterilisation achieved up to a 10.5% increase in oil extraction rate. Crude palm oil with excellent hydrolytic and oxidative stability was acquired, thus, boosting oil value that can facilitate post-processing in palm oil mills.
Additional Metadata
Item Type: | Article |
---|---|
AGROVOC Term: | palm oils |
AGROVOC Term: | steaming |
AGROVOC Term: | heat treatment |
AGROVOC Term: | microwave treatment |
AGROVOC Term: | sterilization |
AGROVOC Term: | research |
AGROVOC Term: | temperature data |
AGROVOC Term: | energy efficiency |
AGROVOC Term: | agricultural productivity |
Geographical Term: | Malaysia |
Uncontrolled Keywords: | energy, microwave, oil palm, stacking, sterilisation. |
Depositing User: | Nor Hasnita Abdul Samat |
Date Deposited: | 29 Apr 2025 01:08 |
Last Modified: | 29 Apr 2025 01:08 |
URI: | http://webagris.upm.edu.my/id/eprint/1752 |
Actions (login required)
![]() |
View Item |