Mohd Zin A. K.., . Water hyacinth system for examination glove factory effluent treatment. pp. 241-256. ISSN 1511-1768
Abstract
Water hyacinth treatment systems provided good removal for biochemical oxygen demand (BOD) and nitrate nitrogen. Ninety six percent removal was achieved for BOD and nitrate nitrogen at loadings of 17 g BOD/m2/day and 9.5 g nitrate nitrogen/m2/day respectively. Removal of 55 and 43 respectively were achieved for ammonium nitrogen and total nitrogen. These removals were obtained at loadings of 2.6 g total nitrogen/m2/day and 1.65 g ammonium nitrogen/m2/day. High concentrations of calcium and nitrate nitrogen seemed to affect BOD and chemical oxygen demand removal efficiencies.
Download File
Full text available from:
Official URL: http://vitaldoc.lgm.gov.my:8060/vital/access/servi...
|
Abstract
Water hyacinth treatment systems provided good removal for biochemical oxygen demand (BOD) and nitrate nitrogen. Ninety six percent removal was achieved for BOD and nitrate nitrogen at loadings of 17 g BOD/m2/day and 9.5 g nitrate nitrogen/m2/day respectively. Removal of 55 and 43 respectively were achieved for ammonium nitrogen and total nitrogen. These removals were obtained at loadings of 2.6 g total nitrogen/m2/day and 1.65 g ammonium nitrogen/m2/day. High concentrations of calcium and nitrate nitrogen seemed to affect BOD and chemical oxygen demand removal efficiencies.
Additional Metadata
Item Type: | Article |
---|---|
AGROVOC Term: | Water hyacinth |
AGROVOC Term: | Wastewater treatment |
AGROVOC Term: | Hydraulic systems |
AGROVOC Term: | Effluents |
AGROVOC Term: | Loading |
AGROVOC Term: | BOD (biochemical oxygen demand) |
AGROVOC Term: | COD (chemical oxygen demand) |
AGROVOC Term: | Environmental control |
Geographical Term: | Malaysia |