Hamzah M. Z., . and Mamat Z. A., . and Bakar N. A., . and Yusoff M. Z., . (2003) Model based optimization of combine cycle power plant operation. In: Issues and research in science: advanced materials and energy. Pusat Penerbitan Universiti (UPENA) Universiti Teknologi Mara, Shah Alam Selangor Malaysia, pp. 325-336. ISBN 967-958-145-4
Abstract
Currently over 40 of the total electrical energy demands in Malaysia are generated by Combined Cycle Gas and Steam Turbines power plant. Consequently even a small improvement in its efficiency will result in large saving in fuel consumption. In a Combi