A rapid and cost effective ultrasonic solvent extraction method for determination of -cyhalothrin and cypermethrin residues in soil


Citation

Halimah Muhamad, . and Badrul Hisyam Zainudin, . and Zulhilmi Z. A. M., . and Nor Kartini Abu Bakar, . A rapid and cost effective ultrasonic solvent extraction method for determination of -cyhalothrin and cypermethrin residues in soil. pp. 377-386. ISSN 1511-2780

Abstract

An effective simple and cost effective ultrasonic solvent extraction procedure was developed for the determination of -cyhalothrin and cypermethrin residues in soil by gas chromatography with electron capture detector (GC-ECD). Several extraction parameters were optimised with regard to the solvent type solvent volume and duration of sonication. Under the optimum conditions recovery studies were performed at five fortification levels (0.01 0.02 0.05 0.1 g g-1). The recovery level ranged from 93.99 to 101.49 and 90.59 to 99.50 for -cyhalothrin and cypermethrin respectively. The relative standard deviation values were less than 4 in all cases. The sensitivitiy of the method was acceptable with limits of detection (LOD) of 0.0025 g g-1 and 0.01 g g-1 for -cyhalothrin and cypermethrin respectively. Finally the proposed method was applied successfully for residue determination of both -cyhalothrin and cypermethrin in soil samples from an oil palm plantation in Labu Negeri Sembilan Malaysia.


Download File

Full text available from:

Abstract

An effective simple and cost effective ultrasonic solvent extraction procedure was developed for the determination of -cyhalothrin and cypermethrin residues in soil by gas chromatography with electron capture detector (GC-ECD). Several extraction parameters were optimised with regard to the solvent type solvent volume and duration of sonication. Under the optimum conditions recovery studies were performed at five fortification levels (0.01 0.02 0.05 0.1 g g-1). The recovery level ranged from 93.99 to 101.49 and 90.59 to 99.50 for -cyhalothrin and cypermethrin respectively. The relative standard deviation values were less than 4 in all cases. The sensitivitiy of the method was acceptable with limits of detection (LOD) of 0.0025 g g-1 and 0.01 g g-1 for -cyhalothrin and cypermethrin respectively. Finally the proposed method was applied successfully for residue determination of both -cyhalothrin and cypermethrin in soil samples from an oil palm plantation in Labu Negeri Sembilan Malaysia.

Additional Metadata

[error in script]
Item Type: Article
AGROVOC Term: Cyhalothrin
AGROVOC Term: Cypermethrin
AGROVOC Term: Ultrasonics
AGROVOC Term: Solvents
AGROVOC Term: Extraction
AGROVOC Term: Flow rate
AGROVOC Term: Experiments
AGROVOC Term: Gas chromatography
AGROVOC Term: Analytical methods
AGROVOC Term: Oil palms