Mohamad Kamal Abdul Kadir, . and Ibtisam E. Tothill, . Optimization of indirect immunoassay for aflatoxin B1 detection. pp. 81-93. ISSN 1394-9829
Abstract
The development of indirect competitive immunoassay formats for the Enzyme Links Immunosorbent Assay (ELISA) construction was undertaken for aflatoxin B1 (AFB1) determination. An indirect assay was based on the competition between an immobilised aflatoxin B1 conjugated with bovine serum albumin (AFB1-BSA conjugate) and the free AFB1 for the binding site of monoclonal antibody against AFB1 (MAbAFB1). Then the secondary anti-antibody IgG labelled with horseradish peroxidase (anti-IgG-HRP conjugate) was used as an enzyme label. A spectrophotometric assay using microtitre plate was used in optimizing the immuno-reagent used for competitive ELISA. The optimal conditions obtained for competitive ELISA were 1 g/ml of BSA-AFB1 10 g/ ml of monoclonal antibody and 1 g/ml of anti-antibody labelled HRP. The linear rage of standard curve (0.1 “ 10 g/litre) was achieved with a detection limit of 0.08 g/litre. The achieved detection range for AFB1 was within the European (2“ 4 g/litre) and Malaysian (5 “ 15 g/litre) required legislative limit of analyses.
Download File
Full text available from:
Official URL: http://ejtafs.mardi.gov.my/jtafs/41-1/Indirect%20i...
|
Abstract
The development of indirect competitive immunoassay formats for the Enzyme Links Immunosorbent Assay (ELISA) construction was undertaken for aflatoxin B1 (AFB1) determination. An indirect assay was based on the competition between an immobilised aflatoxin B1 conjugated with bovine serum albumin (AFB1-BSA conjugate) and the free AFB1 for the binding site of monoclonal antibody against AFB1 (MAbAFB1). Then the secondary anti-antibody IgG labelled with horseradish peroxidase (anti-IgG-HRP conjugate) was used as an enzyme label. A spectrophotometric assay using microtitre plate was used in optimizing the immuno-reagent used for competitive ELISA. The optimal conditions obtained for competitive ELISA were 1 g/ml of BSA-AFB1 10 g/ ml of monoclonal antibody and 1 g/ml of anti-antibody labelled HRP. The linear rage of standard curve (0.1 “ 10 g/litre) was achieved with a detection limit of 0.08 g/litre. The achieved detection range for AFB1 was within the European (2“ 4 g/litre) and Malaysian (5 “ 15 g/litre) required legislative limit of analyses.
Additional Metadata
Item Type: | Article |
---|---|
AGROVOC Term: | Aflatoxins |
AGROVOC Term: | Immunoassay |
AGROVOC Term: | ELISA |
AGROVOC Term: | Aspergillus |
AGROVOC Term: | Enzyme linked immunosorbent assay |
AGROVOC Term: | Serum albumin |
AGROVOC Term: | Monoclonal antibodies |
AGROVOC Term: | Horseradish |
AGROVOC Term: | Peroxidases |
AGROVOC Term: | Indirect ELISA |
Depositing User: | Ms. Suzila Mohamad Kasim |
Last Modified: | 24 Apr 2025 06:29 |
URI: | http://webagris.upm.edu.my/id/eprint/24463 |
Actions (login required)
![]() |
View Item |